P625-3

Minimum Rating

568.8 kVA / 455.0 kW

Maximum Rating

625.0 kVA / 500.0 kW

Emissions/Fuel Strategy

Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Request a Quote

Specifications

Overview

The new 350 – 750 kVA industry leading power range is the result of a continued focus on performance, durability and serviceability combined with the most advanced production methods to deliver power you can trust.

Generator Set Specifications

Minimum Rating 568.8 kVA / 455.0 kW
Maximum Rating 625.0 kVA / 500.0 kW
Voltage 127-480 Volts
Frequency 60 Hz
Speed 1800 RPM
50 Hz Prime – / – – / –
50 Hz Standby – / – – / –
60 Hz Prime 568.8 kVA / 455.0 kW
60 Hz Standby 625.0 kVA / 500.0 kW

Generator Set Configurations

Emissions/Fuel Strategy Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Engine Specifications

Engine Model Perkins® 2506A-E15TAG4
Bore 137.0 mm (5.4 in)
Displacement 15.2l (927.6 cu. in)
Stroke 171.0mm (6.7 in)
Compression Ratio 16.0:1
Governor Type Electronic

Benefits & Features

FG Wilson Diesel Engine

Perkins Engine

Alternator

Benefiting from a choice of leading alternators, the range incorporates the FG Wilson alternator as standard.

PowerWizard 1.1+

The FG Wilson PowerWizard range of digital control panels, combine straightforward menu navigation with advanced metering and protection technology. They are used in automatic mains failure applications in conjunction with transfer panels. Our PowerWizard range allows you to monitor and control your generator set with ease, whilst ensuring your unit operates within safe parameters and provides important diagnostic information when needed.

Design Criteria

Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Single-Source Supplier

Fully prototype tested with certified torsional vibration analysis available

World Wide Product Support

FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India • USA With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.

Equipment

P625-3 Standard Equipment

Engine
  • Air Cleaner
  • Lube oil drain valve
  • Engine filled with lubrication oil
  • High Coolant Temperature Shutdown
  • Low Oil Pressure Shutdown
  • Engine mounted battery charging alternator
Cooling
  • Package mounted radiator
  • Radiator fan and charging alternator guards
  • Coolant Drain Valve
  • Cooling System filled with Coolant mix
Exhaust
  • Exhaust flange outlet
  • Exhaust bellows and gasket
Fuel
  • 8 Hr Fuel Tank
  • BSP Fuel Sockets
Alternator
  • FG Wilson
  • SHUNT Excitation
  • IP21 Protection
Control Panel
  • PowerWizard 1.1+
Mounting
  • Robust steel constructed base frame
  • Base frame drag and lift points
  • Captive linear vibration isolators between base and engine-generator
  • Battery Tray and Cables

P625-3 Optional Equipment

Exhaust
  • Industrial, Residential, Critical Silencers
Alternator
  • Quadrature Droop Kit (AR6)
  • Anti-Condensation Heater and Panel Circuitry (AH1)
  • AREP / PMG excitation
  • AVR Upgrades
  • Three phase sensing
  • Oversize Alternator
  • Coastal ingress protection alternator
  • Leroy Somer upgrade
Control Panels
  • PowerWizard 2.1
  • easYgen-2500
Starting/Charging
  • Heavy duty dry battery
  • Battery charger with auto boost
General
  • Upgrade to Standard Set for “CE” Certification
  • EEC Declaration of Conformity
  • Dual wall base tank (8 hrs)
  • Sound attenuated or High ambient enclosures
  • Battery isolator switch